Rev.  Date Prepared By Protection Cog                  
  71 7/15/2011 Desai Mozulay                  
                                 
    Imin Imax I2T Trep ACP OC Transrex ACP OT ACP TREP ACP I2T ACP Tau RIS OC RIS I2T RIS I2T RIS Tau  
  Headroom->         1.020 Fwd + Rev Time Window         1.050        
    (kA) (kA) (kA2-sec) (sec) (kA) (sec) (sec) (sec) (kA2-sec) (sec) (kA) (kA2-sec) (%) (sec)  
  OH -24 24 265 600 24.5 3.30 3.0 600     25.2 265 100 60  
  PF1A -20 5 1000 600 20.4 3.50 3.0 600              
  PF1B -10 0 250 600 10.2 2.00 " "              
  PF2 -20 0 1000 600 20.4 2.50 " "     21.0 1000 100 200  
  PF3 -5 15 563 600 15.3 3.50 " "     15.8 563 100 600  
  PF4 -15 0 563 600 15.3 2.00 " "              
  PF5 0 20 1000 600 20.4 2.00 " "              
  CHI 0 10 50 600 10.2 2.75 " "              
  TF 0.0 65.2 4750 300 66.5 3.00 3.0 300     68.5 4750 100 130  
  SPA1 -3.3 3.3 27.8 600 3.40 3.00 3.0 300 27.8 4288          
  SPA2 -3.3 3.3 27.8 600 3.40 3.00 3.0 300 27.8 4288          
  SPA3 -3.3 3.3 27.8 600 3.4 3.00 3.0 300 27.8 4288          
  SPA4 -3.3 3.3 27.8 600 3.4 3.00 3.0 300 27.8 4288          
  SPA5 -3.3 3.3 27.8 600 3.4 3.00 3.0 300 27.8 4288          
  SPA6 -3.3 3.3 27.8 600 3.4 3.00 3.0 300 27.8 4288          
  SPA DC Link         1.5   5.0 300 1.0 100          
                OH in 0.5s increments, others 1s increments. SPA DC Link time > trwm due to RC current decay time All PFs same due to common ACP modules New Style ACP w/I2T on RWM & SPA Only New Style ACP w/I2T on RWM & SPA Only          
                                 
  ITF (CHI) 10 (kA)   TF POLARITY (+)           SYSTEM INTERNAL       
                          OC TRIP(kA)      
    PDP Timers                 SPA1 3.34      
    Duration Trep                 SPA2 3.34      
    (sec) (sec)                 SPA3 3.34      
  ALL SYSTEMS 4 300