Subject: Everson Visit #16 TF BUNDLE UPDATE Tom Meighan and I visited Everson Electric Co. this morning to inspect the TF bundle following its removal from the press mold. The outside surface of the cured bundle looked extremely good with no indications of dry areas. Dimensional checks were made of the diameter every 2 feet along its length. All of the dimensions are below our maximum size of 7.924 inches which is required to match with the OH coil and tension tube assembly. Work will begin shortly on refurbishing the electrical joint areas of the TF bundle. Later this week work will also begin on restoring the Kapton shields between the outer TF conductor electrical pads. The tension tube is scheduled to be at Everson on Monday February 2, 1998 with winding of the OH coil to begin later that week. Jim C.